Download Free Westinghouse Owners Group Report Reactor Coolant Pump Seal Performance Following A Loss Of All Ac Power Book in PDF and EPUB Free Download. You can read online Westinghouse Owners Group Report Reactor Coolant Pump Seal Performance Following A Loss Of All Ac Power and write the review.

Results are presented from an investigation into the behavior of Reactor Coolant Pump shaft seals during a potential station blackout (loss of all ac power) at a nuclear power plant. The investigation assumes loss of cooling to the seals and focuses on the effect of high temperature on polymer seals located in the shaft seal assemblies, and the identification of parameters having the most influence on overall hydraulic seal performance. Predicted seal failure thresholds are presented for a range of station blackout conditions and shaft seal geometries.