Download Free Spill Prevention And Countermeasures Plan Book in PDF and EPUB Free Download. You can read online Spill Prevention And Countermeasures Plan and write the review.

This manual guides Navy areas in developing and implementing their Spill Prevention, Control, and Countermeasure plan (SPCC Plan) for oil and hazardous substances (HS). This document is required by the Environmental Protection Agency (EPA) Part 40 of the Code of Federal Regulation, Section 112 (20 CFR 112), the Oil Pollution Prevention regulation, and OPNAVINST 5090.1B, for oil area meeting the criteria in 40 CFR 112. Spill control measures are required for hazardous waste (HW) storage areas regulated by either 40 CFR 264 or 40 CFR 265. Additionally, some spill control measures are required for underground storage tanks (UST) regulated by 40 CFR 280. HW storage areas, not specifically regulated by the above referenced regulations, do not have regulated spill control requirements; however, it is considered best engineering practice to have spill control measures at all HS storage areas. Therefore, it is recommended that all HS storage areas be included in Navy SPCC plans. For overseas locations please refer to OEBGD/FGS criteria for spill prevention guidance.
The purposes of the spill prevention control and countermeasure plan (SPCC) is to prevent and control the discharge of oil and hazardous substances at RMA. The SPCC plan identifies potential sources of oil and hazardous substances and the measures required to prevent accidental discharge resulting from equipment or storage facility failure. In the event that a spill occurs, the SPCC plan identified the means to control, contain and cleanup the discharge. The SPCC plan is directed by the U.S. EPA regulations and the U.S. Army regulations. The SPCC plan for RMA is organized as follows: project background is provided, detailed descriptions of the individual tanks are provided, The installation spill contingency (ISC) plan is presented, the security at each of the tank areas is discussed, a description is provided of the types of training procedures for RMA personnel, and reporting requirements are presented, including the regulatory agencies which need to be contacted if an accidental spill occurs.
The main objective of the project during the summer internship at CalPortland Company was creating "Spill Prevention, Control and Countermeasure (SPCC) Plan" for the company's Colton aggregate plant. The SPCC plan is required by 40 CFR Section 112, oil pollution prevention, of the Environmental Protection agency in order to prevent the discharge of oil from non-transportation-related onshore and offshore facilities into or upon the navigable waters of the United States or adjoining shorelines ("ECFR---code of federal regulations," 2016). Previously, CalPortland company's Colton plant operated as a cement plant until it was permanently shut down in the year of 2009, and many documents have been lost or misplaced ever since. Since then the plant restarted operations but this time as an aggregates plant which still requires an SPCC plan since it stores and uses oil products that are in the amounts requiring current SPCC plan. Thus, as an environmental engineering intern I was assigned to study all of the rules, and regulations set by environmental protection agency for the preparation and implementation of "Spill Prevention, Control and Countermeasure Plan" which eventually became company's official plan after it was approved and signed by my internship mentor, Licensed Engineer Desirea Haggard.
This spill prevention, control and countermeasures (SPCC) Plan is divided into two volumes. Volume I addresses Y-12's compliance with regulations pertinent to the content of SPCC Plans. Volume II is the SPCC Hazardous Material Storage Data Base, a detailed tabulation of facility-specific information and data on potential spill sources at the Y-12 Plant. Volume I follows the basic format and subject sequence specified in 40 CFR 112.7. This sequence is prefaced by three additional chapters, including this introduction and brief discussions of the Y-12 Plant's background/environmental setting and potential spill source categories. Two additional chapters on containers and container storage areas and PCB and PCB storage for disposal facilities are inserted into the required sequence. The following required subjects are covered in this volume: Spill history, site drainage; secondary containment/diversion structures and equipment; contingency plans; notification and spill response procedures; facility drainage; bulk storage tanks; facility transfer operations, pumping, and in-plant processes; transfer stations (facility tank cars/tank tracks); inspections and records; security, and personnel, training, and spill prevention procedures.
The purpose of this Chemical Spill Prevention, Control, and Countermeasures (SPCC) Plan is to identify the chemical spill control practices, procedures, and containment devices Westinghouse Hanford Company (Westinghouse Hanford) employs to prevent a reportable quantity (RQ) of a hazardous substance (as defined in 40 CFR Part 302) from being released to the environment. The chemical systems and chemical storage facilities in the 100 Areas are described. This document traces the ultimate fate of accidental chemical spills at the 100 Areas. Also included in the document destinations, spill containment devices, and systems surveillance frequencies. 2 tabs.