Download Free Quality Assurance Programme For Computed Tomography Book in PDF and EPUB Free Download. You can read online Quality Assurance Programme For Computed Tomography and write the review.

This publication presents a harmonized approach to quality assurance in the field of computed tomography applied to both diagnostics and therapy. It gives a careful analysis of the principles and specific instructions that can be used for a quality assurance programme for optimal performance and reduced patient dose in diagnostic radiology. In some cases, radiotherapy programmes are making a transition from 2-D to 3-D radiotherapy, a complex process which critically depends on accurate treatment planning. In this respect, the authors also provide detailed information about the elements needed for quality assurance testing, including those relating to accurate patient characterization as needed for radiotherapy treatment planning.
This publication provides guidelines for the implementation of quality assurance and control programs concerning the combined medical diagnostic modality of positron emission tomography (PET) and computed tomography (CT). These independent, but complementary, imaging techniques are in frequent and increasing use within the fields of diagnostic imaging, oncology, cardiology and neurology, where they allow physicians to locate and diagnose malignant diseases accurately. This publication establishes guidelines for acceptance testing and routine quality control as necessary for optimal clinical performance. Specific topics of discussion include frameworks for reference values, tolerances and action levels, minimal required configurations with corresponding performances characteristics, and the management of ancillary equipment.
This publication presents a harmonized approach to quality assurance in the field of computed tomography applied to both diagnostics and therapy. It gives a careful analysis of the principles and specific instructions that can be used for a quality assurance programme for optimal performance and reduced patient dose in diagnostic radiology. In some cases, radiotherapy programmes are making a transition from 2-D to 3-D radiotherapy, a complex process which critically depends on accurate treatment planning. In this respect, the authors also provide detailed information about the elements needed.
Quality assurance (QA) is a crucial part of all aspects of nuclear medicine practice. The objective of this publication is to provide professionals in nuclear medicine centers with detailed quality control test procedures for the scintillation camera and computer system. Three types of quality tests are described in detail: acceptance, reference and routine tests for the scintillation camera, both in single and multiple head configurations, for obtaining images and quantitative data in planar imaging mode; whole body imaging mode; and single-photon emission computed tomography (SPECT). The publication is primarily intended to be of use to medical physicists, technologists, and other healthcare professionals who are responsible for ensuring optimal performance of imaging instruments, particularly SPECT systems. It may also be useful to managers, clinicians, and other decision-makers who are responsible for implementing quality assurance and quality control programs in nuclear medicine c
This comprehensive textbook provides a state of the art overview of the means by which quality in patient care is ensured within the field of nuclear medicine. Acknowledged experts in the field cover both management aspects, such as laws, standards, guidelines, patient safety, management instruments, and organisations, and specific issues, including radiation safety and equipment. Quality in Nuclear Medicine not only presents detailed information on the topics discussed but should also stimulate further discussion and offer an important tool to all professionals in the field of nuclear medicine and their stakeholders. Readers will find that the book provides a wealth of excellent guidance and reflects the pioneering role of nuclear medicine in advancing different aspects of quality within medicine.
SPECT/CT Atlas of Quality Control and Image Artefacts
Build the foundation necessary for the practice of CT scanning with Computed Tomography: Physical Principles, Patient Care, Clinical Applications, and Quality Control, 5th Edition. Written to meet the varied requirements of radiography students and practitioners, this two-color text provides comprehensive coverage of the physical principles of computed tomography and its clinical applications. The clear, straightforward approach is designed to improve your understanding of sectional anatomic images as they relate to computed tomography and facilitate communication between CT technologists and other medical personnel. - Chapter outlines and chapter review questions help you focus your study time and master content. - NEW! Three additional chapters reflect the latest industry CT standards in imaging: Radiation Awareness and Safety Campaigns in Computed Tomography, Patient Care Considerations, and Artificial Intelligence: An Overview of Applications in Health and Medical Imaging. - UPDATED! More than 509 photos and line drawings visually clarify key concepts. - UPDATED! The latest information keeps you up to date on advances in volume CT scanning; CT fluoroscopy; and multislice applications like 3-D imaging, CT angiography, and virtual reality imaging (endoscopy).
Comprehensive medical imaging physics notes aimed at those sitting the first FRCR physics exam in the UK and covering the scope of the Royal College of Radiologists syllabus. Written by Radiologists, the notes are concise and clearly organised with 100's of beautiful diagrams to aid understanding. The notes cover all of radiology physics, including basic science, x-ray imaging, CT, ultrasound, MRI, molecular imaging, and radiation dosimetry, protection and legislation. Although aimed at UK radiology trainees, it is also suitable for international residents taking similar examinations, postgraduate medical physics students and radiographers. The notes provide an excellent overview for anyone interested in the physics of radiology or just refreshing their knowledge. This third edition includes updates to reflect new legislation and many new illustrations, added sections, and removal of content no longer relevent to the FRCR physics exam. This edition has gone through strict critique and evaluation by physicists and other specialists to provide an accurate, understandable and up-to-date resource. The book summarises and pulls together content from the FRCR Physics Notes at Radiology Cafe and delivers it as a paperback or eBook for you to keep and read anytime. There are 7 main chapters, which are further subdivided into 60 sub-chapters so topics are easy to find. There is a comprehensive appendix and index at the back of the book.
Positron emission tomography/computed tomography (PET/CT), as any other imaging modality, is acceptable for routine clinical and research applications only if technical pitfalls can be avoided. Artefacts from incorrect or sub-optimal acquisition procedures should be recognized and, if possible, corrected retrospectively and the resulting image information interpreted correctly, which entails an appreciation of variants of the represented image information. This publication provides guidance on the physics and technical aspects behind PET and PET/CT image distortions. Cases are presented to provide nuclear medicine and radiology professionals with an assortment of examples of possible image distortions and errors in order to support a correct image interpretation. Nearly 70 typical PET and PET/CT cases, comprising image sets and cases, have been collected in this volume, all catalogued and augmented with explanations as to the causes of, and solutions to, each individual image problem. The atlas will prove useful to physicists, physicians, technologists, and service engineers in the clinical field.
This manual provides a harmonized approach to quality assurance (QA) in the emerging area of digital mammography. It outlines the principles of, and specific instructions that can be used for, a QA programme for the optimal detection of early stage breast cancer within a digital environment. Intended for use by Member States that are now using digital mammography or that are assessing the implications of using digital mammography, it addresses major areas such as considerations concerning the transition from screen film to digital mammography, basic principles of QA, clinical image quality, quality control tests for radiographers, and quality control tests for medical physicists, including dosimetry assessment. Instructional materials to supplement the knowledge of professionals already working in the field of diagnostic radiology, as well as quality control worksheets, are also provided.