Download Free Bond And Anchorage Of Embedded Reinforcement Background To The Fib Model Code For Concrete Structures 2010 Book in PDF and EPUB Free Download. You can read online Bond And Anchorage Of Embedded Reinforcement Background To The Fib Model Code For Concrete Structures 2010 and write the review.

As part of the preparation for the fib Model Code for Concrete Structures 2010, task group 4.5 Bond Models undertook a major review of rules for bond and anchorage of reinforcement in the CEB-FIP Model Code 1990. This bulletin presents the outcome of that review, describes the rationale for the revisions and presents the evidence on which the revisions are based. The principle changes in MC2010 include raising the limit on concrete strength that may be used when determining bond resistance to 110MPa, introduction of a coefficient η4 to cater for different reinforcement Classes, and coverage of new construction materials including epoxy coated and headed bars. The format of design rules has been changed to permit more rational treatment of confinement from concrete cover and transverse reinforcement, the contribution of end hooks and bends for tension bars, and end bearing to compression laps. New guidance is provided covering a range of construction techniques and service environments and the influence of long term degradation. Analyses of various aspects of detailing on performance of laps and anchorages have resulted in discontinuation of the ‘proportion lapped’ factor α6, alterations to requirements of transverse reinforcement at laps, and have resolved inconsistencies in provisions for bundled bars between major national codes. Apparent inconsistencies in existing rules for lapped joints and anchorages and between the local bond/slip model and design rules are also resolved, thus allowing integration of application rules and modelling. Finally, the basis for an attempt to introduce simple detailing rules for laps and anchorages is described.
The International Federation for Structural Concrete (fib) is a pre-normative organization. 'Pre-normative' implies pioneering work in codification. This work has now been realized with the fib Model Code 2010. The objectives of the fib Model Code 2010 are to serve as a basis for future codes for concrete structures, and present new developments with regard to concrete structures, structural materials and new ideas in order to achieve optimum behaviour. The fib Model Code 2010 is now the most comprehensive code on concrete structures, including their complete life cycle: conceptual design, dimensioning, construction, conservation and dismantlement. It is expected to become an important document for both national and international code committees, practitioners and researchers. The fib Model Code 2010 was produced during the last ten years through an exceptional effort by Joost Walraven (Convener; Delft University of Technology, The Netherlands), Agnieszka Bigaj-van Vliet (Technical Secretary; TNO Built Environment and Geosciences, The Netherlands) as well as experts out of 44 countries from five continents.
Reinforced concrete has long been a cornerstone of modern construction, offering strength, durability, and versatility in building structures of all types. As the demand for sustainable, high-performance materials grows, so does the need for continued innovation and advancement in this field. This comprehensive collection of articles brings together the latest research and insights into the many aspects of reinforced concrete. From materials and properties to design and optimization, and even the identification of pathologies and the effects of corrosion, each section offers valuable knowledge and expertise. With contributions from leading experts in the field, this collection provides a comprehensive overview of the latest innovations and research in reinforced concrete. It is an essential resource for researchers, engineers, and practitioners seeking to stay up to date with the latest advancements in this important field.
This Proceedings contains the papers of the fib Symposium “CONCRETE Innovations in Materials, Design and Structures”, which was held in May 2019 in Kraków, Poland. This annual symposium was co-organised by the Cracow University of Technology. The topics covered include Analysis and Design, Sustainability, Durability, Structures, Materials, and Prefabrication. The fib, Fédération internationale du béton, is a not-for-profit association formed by 45 national member groups and approximately 1000 corporate and individual members. The fib’s mission is to develop at an international level the study of scientific and practical matters capable of advancing the technical, economic, aesthetic and environmental performance of concrete construction. The fib, was formed in 1998 by the merger of the Euro-International Committee for Concrete (the CEB) and the International Federation for Prestressing (the FIP). These predecessor organizations existed independently since 1953 and 1952, respectively.
fib Bulletin 81 reports the latest information available to researchers and practitioners on the analysis, design and experimental evidence of punching shear of structural concrete slabs. It follows previous efforts by the International Federation for Structural Concrete (fib) and its predecessor the Euro-International Committee for Concrete (CEB), through CEB Bulletin 168, Punching Shear in Reinforced Concrete (1985) and fibBulletin 12, Punching of structural concrete slabs (2001), and an international symposium sponsored by the punching shear subcommittee of ACI Committee 445 (Shear and Torsion) and held in Kansas City, Mo., USA, in 2005. This bulletin contains 18 papers that were presented in three sessions as part of an international symposium held in Philadelphia, Pa., USA, on October 25, 2016. The symposium was co-organized by the punching shear sub-committee of ACI 445 and by fib Working Party 2.2.3 (Punching and Shear in Slabs) with the objectives of not only disseminating information on this important design subject but also promoting harmonization among the various design theories and treatment of key aspects of punching shear design. The papers are organized in the same order they were presented in the symposium. The symposium honored Professor Emeritus Neil M. Hawkins (University of Illinois at Urbana-Champaign, USA), whose contributions through the years in the field of punching shear of structural concrete slabs have been paramount. The papers cover key aspects related to punching shear of structural concrete slabs under different loading conditions, the study of size effect on punching capacity of slabs, the effect of slab reinforcement ratio on the response and failure mode of slabs, without and with shear reinforcement, and its implications for the design and formulation in codes of practice, an examination of different analytical tools to predict the punching shear response of slabs, the study of the post-punching response of concrete slabs, the evaluation of design provisions in modern codes based on recent experimental evidence and new punching shear theories, and an overview of the combined efforts undertaken jointly by ACI 445 and fib WP 2.2.3 to generate test result databanks for the evaluation and calibration of punching shear design recommendations in North American and international codes of practice.
In 1994 fib Commission 6: Prefabrication edited a successful Planning and Design Handbook that ran to approximately 45,000 copies and was published in Spanish and German. Nearly 20 years later Bulletin 74 brings that first publication up to date. It offers a synthesis of the latest structural design knowledge about precast building structures against the background of 21st century technological innovations in materials, production and construction. With it, we hope to help architects and engineers achieve a full understanding of precast concrete building structures, the possibilities they offer and their specific design philosophy. It was principally written for non-seismic structures. The handbook contains eleven chapters, each dealing with a specific aspect of precast building structures. The first chapter of the handbook highlights best practice opportunities that will enable architects, design engineers and contractors to work together towards finding efficient solutions, which is something unique to precast concrete buildings. The second chapter offers basic design recommendations that take into account the possibilities, restrictions and advantages of precast concrete, along with its detailing, manufacture, transport, erection and serviceability stages. Chapter three describes the precast solutions for the most common types of buildings such as offices, sports stadiums, residential buildings, hotels, industrial warehouses and car parks. Different application possibilities are explored to teach us which types of precast units are commonly used in all those situations. Chapter four covers the basic design principles and systems related to stability. Precast concrete structures should be designed according to a specific stability concept, unlike cast in-situ structures. Chapter five discusses structural connections. Chapters six to nine address the four most commonly used systems or subsystems of precast concrete in buildings, namely, portal and skeletal structures, wall-frame structures, floor and roof structures and architectural concrete facades. In chapter ten the design and detailing of a number of specific construction details in precast elements are discussed, for example, supports, corbels, openings and cutouts in the units, special features related to the detailing of the reinforcement, and so forth. Chapter eleven gives guidelines for the fire design of precast concrete structures. The handbook concludes with a list of references to good literature on precast concrete construction.
For a large part of the existing buildings and infrastructure the design life has been reached or will be reached in the near future. These structures might need to be reassessed in order to investigate whether the safety requirements are met. Current practice on the assessment of existing concrete structures however needs a thorough evaluation from a risk and reliability point of view, as they are mostly verified using simplified procedures based on the partial factor method commonly applied in design of new structures. Such assessments are often conservative and may lead to expensive upgrades. Although the last decades reliability-based assessment of existing concrete structures has gained wide attention in the research field, a consistent reliability-based assessment framework and a practically applicable codified approach which is compatible with the Eurocodes and accessible for common structural engineering problems in everyday practice is currently missing. Such an approach however allows for a more uniform, more objective and probably more widely applied assessment approach for existing concrete structures. Hence, in this bulletin two different partial factor formats are elaborated, i.e. the Design Value Method (DVM) and the Adjusted Partial Factor Method (APFM), enabling the incorporation of specific reliability related aspects for existing structures. The DVM proposes a fundamental basis for evaluating partial factors whereas the APFM provides adjustment factors to be applied on the partial factors for new structures in EN 1990. In this bulletin both methods are elaborated and evaluated and a basis is provided for decision making regarding the target safety level of existing structures.
The purpose of this recommendation - fib Bulletin 75: Polymer-duct systems for internal bonded post-tensioning - is to update and amend fib Bulletin 7:Corrugated plastic ducts for internal bonded post-tensioning, a technical report published in 2000. fib Bulletin 75 is meant as a cornerstone for the technical approval of polymer (plastic) ducts for internal bonded post-tensioning and possibly for the test procedures of a future testing standard. The updated bulletin includes new information on the design and detailing of concrete structures containing tendons with polymer ducts. The recommendation provides detailed test specifications for polymer materials, duct components and duct systems. In addition, the report contains recommendations for approval testing and attestations of conformity for polymer-duct systems. Although the new generation of corrugated polymer ducts for bonded post-tensioning have now been around for approximately twenty years, products still differ in material properties, geometrical detail, installation procedures and on-site use. Unlike corrugated steel ducts or smooth polyethylene (PE) pipes, they have not yet become standardized. It is the opinion of fib Task Group 9.16 and Commission 9 that these plastic ducts should, therefore, still be subjected to a systems approval process. This recommendation offers information acquired from twenty years of experience as well as new specifications that will, hopefully, lead to the standardization of polymer-duct systems.
The fib has two major missions now. One is to work toward the publication of the Model Code 2020, and the other is to respond to the global movement toward carbon neutrality. While the former is steadily progressing toward completion, the latter will require significant efforts for generations to come. As we all know, cement, the primary material for concrete, is a sector that accounts for 8.5% of the world’s CO2 emissions. And the structural concrete that fib handles consume 60% of that. In other words, we need to know the reality that our structural concrete is emitting 5% of the world’s CO2. From now on, fib members, suppliers, designers, builders, owner’s engineers, and academic researchers will be asked how to solve this difficult problem. In general, most of the CO2 emissions in the life cycle of structural concrete come from the production stage of materials and the use stage after construction, i.e. A1 to A3 and B1 to B5 processes as defined in EN15978. Cement and steel sectors, which are the main materials for structural concrete, are expected to take various measures to achieve zero carbon in their respective sectors by 2050. Until then, we must deal with the transition with our low carbon technologies. Regarding the production stage, the fib has recently launched TG4.8 “Low carbon concrete”. And the latest low carbon technologies will be discussed there. On the other hand, in the use stage, there is very little data on the relationship between durability and intervention and maintenance so far. The data accumulation here is the work of the fib, a group of various experts on structural concrete. Through-life management using highly durable structures and precise monitoring will enable to realize minimum maintenance in the use stage and to minimize CO2 emissions. Furthermore, it is also possible to contribute to the reduction of CO2 emissions in the further stage after the first cycle by responding to the circular economy, that is, deconstruction (C), reuse, and recycle (D). However, the technology in this field is still in its infancy, and further research and development is expected in the future. As described above, structural concrete can be carbon neutral in all aspects of its conception, and it can make a significant contribution when it is realized. The fib will have to address these issues in the future. Of course, it will not be easy, and it will take time. However, if we do not continue our efforts as the only international academic society on structural concrete in the world to achieve carbon neutrality, the significance of our very existence may be questioned. Long before Portland cement was invented, Roman concrete, made of volcanic ash and other materials, was the ultimate low-carbon material, and is still in use 2’000 years later because of its non-reinforced structure and lack of deterioration factors. Reinforced concrete, which made it possible to apply concrete to structures other than arches and domes, is only 150 years old. Prestressed concrete is even younger, with only 80 years of history. Now that we think about it, we realize that Roman concrete, which is non-reinforced low carbon concrete, is one of the examples of problem solving that we are trying to achieve. We have new materials, such as coated reinforcement, FRP, and fiber reinforced concrete, which can be used in any structural form. To overcome this challenge with all our wisdom would be to live up to the feat the Romans accomplished 2’000 years ago. Realizing highly durable and elegant structures with low-carbon concrete is the key to meet the demands of the world in the future. I hope you will enjoy reading this AOS brochure showing the Outstanding Concrete Structures Awards at the fib 2022 Congress in Oslo. And I also hope you will find some clues for the challenges we are facing.
Standards for specifying and ensuring the durability of new concrete structures are commonly of the prescriptive kind. fib Bulletin 76: Benchmarking of deemed-to-satisfy provisions in standards - Durability of reinforced concrete structures exposed to chlorides presents the benchmarking of a number of rules for chloride-induced corrosion as given in national codes such as European, US and Australian standards. This new benchmark determines the reliability ranges in the chloride-induced depassivation of rebar if the deemed-to-satisfy rules of different countries are taken into consideration. It does not only involve (probabilistic) calculations using input mainly based on short-term and rapid laboratory-test data but also involves input based on an independent assessment of existing structures. The reliability analyses are carried out using the probabilistic design approach for chloride-induced corrosion presented in fib Bulletin 34: Model Code for Service Life Design (2006), fib Model Code for Concrete Structures 2010 and ISO 16204:2012. The work compares the calculated reliability ranges thus determined with the target reliabilities proposed by current specifications and, based on the comparison, offers a proposal for the improvement of deemed-to-satisfy rules and specifications. fib Bulletin 76 presents and discusses in detail the input data for the examined model parameters and offers an extensive annexe documenting the values of the individual parameters used in the analyses. It thus provides a reliable database for the performance-based probabilistic service-life design of concrete structures exposed to chlorides, be they in the form of salt fog, sea water or de-icing salts.