Quality Control and Artefacts in Magnetic Resonance Imaging is an authoritative, comprehensive and practical guide for all medical imaging professionals with an interest in evaluating and assuring image quality and scanner performance in MRI. Written by leading UK experts, the report is a major revision of IPEM Report 80: Quality Control in Magnetic Resonance Imaging. The report is in two parts. Part I deals with quality control, with chapters on test object design and test materials, signal parameter measurement (signal-to-noise ratio, ghosting, etc.), geometric parameters (resolution, distortion), slice parameters (position, width and profile), relaxometry and contrast. For each parameter a consistent and systematic structure provides a literature review with reference to current international standards, parameter definition, description of test methods, practical guidance including frequency of measurement, analysis and interpretation of results, and pitfalls. A specialist QC chapter is a new and unique feature providing guidance relating to specific clinical and research techniques: field mapping, diffusion, BOLD fMRI, voxel-based morphometry, dynamic contrast-enhanced MRI, quantitative velocity mapping, spectroscopy, and ultra-high field MRI. Part II provides a comprehensive and exhaustive encyclopaedia of MRI artefacts both common and rare arising from technical limitations and faults, patient and organ motion, tissue properties, intrinsic MR physics, and reconstruction limitations. Pictorial examples of each artefact from clinical or phantom images are provided along with a detailed explanation of the causes and advice on reducing, avoiding or removing the artefact. A summary table of artefact appearance, causes and remediation will enable readers to diagnose and solve their own artefact problems. The practical nature of the report is underpinned by academic rigour with 269 references and a comprehensive index. Quality Control and Artefacts in Magnetic Resonance is an essential reference for all MRI departments and MRI professionals.
MR is a powerful modality. At its most advanced, it can be used not just to image anatomy and pathology, but to investigate organ function, to probe in vivo chemistry, and even to visualise the brain thinking. However, clinicians, technologists and scientists struggle with the study of the subject. The result is sometimes an obscurity of understanding, or a dilution of scientific truth, resulting in misconceptions. This is why MRI from Picture to Proton has achieved its reputation for practical clarity. MR is introduced as a tool, with coverage starting from the images, equipment and scanning protocols and traced back towards the underlying physics theory. With new content on quantitative MRI, MR safety, multi-band excitation, Dixon imaging, MR elastography and advanced pulse sequences, and with additional supportive materials available on the book's website, this new edition is completely revised and updated to reflect the best use of modern MR technology.