National Aeronautics and Space Administration (NASA)
Published: 2018-07-25
Total Pages: 302
Get eBook
A laser anemometer system was used to provide detailed surveys of the three-dimensional velocity field within the NASA low-speed centrifugal impeller operating with a vaneless diffuser. Both laser anemometer and aerodynamic performance data were acquired at the design flow rate and at a lower flow rate. Floor path coordinates, detailed blade geometry, and pneumatic probe survey results are presented in tabular form. The laser anemometer data are presented in the form of pitchwise distributions of axial, radial, and relative tangential velocity on blade-to-blade stream surfaces at 5-percent-of-span increments, starting at 95-percent-of-span from the hub. The laser anemometer data are also presented as contour and wire-frame plots of throughflow velocity and vector plots of secondary velocities at all measurement stations through the impeller. Hathaway, Michael D. and Chriss, Randall M. and Strazisar, Anthony J. and Wood, Jerry R. Glenn Research Center NASA-TP-3527, E-9390, NAS 1.60:3527, ARL-TR-333 RTOP 505-62-52; DA PROJ. 1L1-61102-AH-45...