Download Free Evaluation Findings For Earthquake Protection Systems Inc Book in PDF and EPUB Free Download. You can read online Evaluation Findings For Earthquake Protection Systems Inc and write the review.

Prepared by the Highway Innovative Technology Evaluation Center (HITEC), a CERF Service Center. This report summarizes the results of a detailedØevaluation of Friction Pendulum Bearings,Ømanufactured by Earthquake Protection Systems, Inc. The report is part of a program to test the performance of 11 seismic isolators and dampers produced by several manufacturers. The devicesØwere tested for stability, response during earthquake simulations, and fatigue and weathering effects.
Prepared by the Highway Innovative Technology Evaluation Center (HITEC), a CERF Service Center. his report summarizes the results of an evaluation that was designed to test the performance of 11 seismic isolators and dampers. The devices were tested for stability, response during earthquake simulations, and fatigue and weathering effects.
The Rapid Visual Screening (RVS) handbook can be used by trained personnel to identify, inventory, and screen buildings that are potentially seismically vulnerable. The RVS procedure comprises a method and several forms that help users to quickly identify, inventory, and score buildings according to their risk of collapse if hit by major earthquakes. The RVS handbook describes how to identify the structural type and key weakness characteristics, how to complete the screening forms, and how to manage a successful RVS program.
Prepared by the Highway Innovative Technology Evaluation Center (HITEC), a CERF service center. This report presents the results of a detailed evaluation ofØthe MX 30 pavement marking 30-meter retroreflectometer. The evaluation is designed to test the measurement bias, repeatability, and reproducibility of handheld and mobile retroreflectometers produced by several manufacturers.
Presents the results of a detailed evaluation for one technology out of eleven that were evaluated. The evaluations were designed to test the performance of seismic isolators and dampers produced by several manufacturers.
Prepared by the Highway Innovative Technology Evaluation Center (HITEC), a CERF Service Center. This report summarizes the results of a detailedØevaluation of a viscous damper,Ømanufactured by Enidine, Inc. The report is part of a program to test the performance of 11 seismic isolators and dampers produced by several manufacturers. The devicesØwere tested for stability, response during earthquake simulations, and fatigue and weathering effects.
Prepared by the Highway Innovative Technology Evaluation Center, a CERF service center. This report presents the results of a HITEC evaluation of the Isogrid Retaining Wall System, designed and developed by the Neel Company. The report describes the basic capabilities and limitations of the Isogrid System for use as a technically viable precast, mechanically stabilized earth retaining wall system. The evaluation was conducted based on material, design, construction, performance, and quality assurance information outlined in the HITEC Protocol. The Isogrid System features a diamond-shaped, segmental precast concrete facing panel with weep holes where four panels intersect and welded wire, grid-type soil reinforcement attached to the center of each facing panel.
Prepared by the Environmental Technology Evaluation Center (EvTEC), a CERF Service Center. This report describes the nature and scope of an environmental evaluation of ThermoEnergy Corporation's Ammonia Recovery Process (ARP) System, a method for recycling ammonia in wastewater. The data in this report were collected over a three-month pilot study.ØTests found that the ARP system is capable of removing 75?99% of the ammonia in the waste stream in a domestic wastewater treatment plant. The ARP System uses a series of absorption, evaporation, and crystallization steps to convert ammonia in wastewater into a commercial fertilizer, ammonium sulfate. The evaluation results clearly indicate that the ARP process is capable of achieving significant ammonia reduction under a range of environmental conditions
This book addresses applications of earthquake engineering for both offshore and land-based structures. It is self-contained as a reference work and covers a wide range of topics, including topics related to engineering seismology, geotechnical earthquake engineering, structural engineering, as well as special contents dedicated to design philosophy, determination of ground motions, shock waves, tsunamis, earthquake damage, seismic response of offshore and arctic structures, spatial varied ground motions, simplified and advanced seismic analysis methods, sudden subsidence of offshore platforms, tank liquid impacts during earthquakes, seismic resistance of non-structural elements, and various types of mitigation measures, etc. The target readership includes professionals in offshore and civil engineering, officials and regulators, as well as researchers and students in this field.
Prepared by CEITEC, a CERF innovation center serving the engineering and construction industries. This report describes an evaluation of Sewer Scanner and Evaluation Technology (SSET) designed to determine the basic capabilities and limitations of SSET for use as a technicallly viable technology for inspecting sewer pipes. The evaluation focused on the performance and in-service demonstration of SSET. The technology involves digital scanning to obtain a flat, "unfolded" image of the pipeline's interior. This evaluation includes field demonstrations performed at 13 municipal public works agencies throughout North America. Subsequent to this evaluation, SSET was modified to include a fisheye lens camera and fiber optic gyroscope, which replaced the rotating mechanical scanner and mechanical gyroscope. The evaluation confirmed the operability of SSET and its viability in data presentation. A degree of enhancement was recognized with additional features, most notably the ability to produce a digital report of the sewer pipe, to identify vertical deflection in pipes, and to deliver easily comprehensible and manageable results. The evaluation also revealed that SSET cannot reproduce all the features typically available from closed-circuit television (CCTV) inspection. Such features include the ability to clearly see corrosion, infiltration rates, and ovality. The limitations in applicability were determined and an economic comparison of SSET and CCTV is provided.