Download Free Calibration Principles And Procedures For Field Strength Meters 30 Hz To 1 Ghz Book in PDF and EPUB Free Download. You can read online Calibration Principles And Procedures For Field Strength Meters 30 Hz To 1 Ghz and write the review.

The National Bureau of Standards has been calibrating many types of field strength meters and their related antennas at frequencies up to 1000 MHz for several years.Various techniques of measurement have been * investigated regarding accuracy, calibration.
Excerpt from Calibration Principles and Procedures for Field Strength Meters 30 (Hz to 1ghz) The National Bureau of Standards has been calibrating many types of field strength meters and their related antennas at frequencies up to 1000 mhz for several years. Various techniques of measurement have been investigated regarding accuracy, calibration time, ease of operation, and reliability. This report discusses some of these calibration tech niques in detail, and in some cases lists step-by-step procedures for per forming the complete calibration. Typical calibration data are used to take the reader from the beginning of the calibration to the completed test report. All measurement setups are clearly illustrated, listing the equip ment necessary to perform the calibration. Methods of calibrating two basic types of antennas are described: (1) the loop antenna at frequencies from 30 Hz to 30 mhz and (2) half-wavelength dipole antennas from 30 to 1000 mhz. Two methods of calibrating loop antennas are discussed in de tail, the standard-field method and the injection method. The standard antenna method of calibrating dipole antennas is fully described. Measure ment uncertainties of various methods are discussed. This report was written to help technical personnel actively participate in antenna cali bration work. Hopefully this information will help people to set up new calibration services and to improve existing calibrating facilities. About the Publisher Forgotten Books publishes hundreds of thousands of rare and classic books. Find more at www.forgottenbooks.com This book is a reproduction of an important historical work. Forgotten Books uses state-of-the-art technology to digitally reconstruct the work, preserving the original format whilst repairing imperfections present in the aged copy. In rare cases, an imperfection in the original, such as a blemish or missing page, may be replicated in our edition. We do, however, repair the vast majority of imperfections successfully; any imperfections that remain are intentionally left to preserve the state of such historical works.
The National Bureau of Standards has been calibrating many types of field strength meters and their related antennas at frequencies up to 1000 MHz for several years.Various techniques of measurement have been * investigated regarding accuracy, calibration.